Three Phases Dry Type cast resin Transformer with ANAF cooling way

Brand Name : Pearl Electric
Model Number : PEC-S-100/11
Certification : KEMA, CE, CCC, ISO9001
Place of Origin : China
MOQ : 1 unit
Price : 5000USD/Set
Payment Terms : T/T, L/C
Supply Ability : 9000 units per year
Delivery Time : 30days-50days ex-work
Packaging Details : Seaworthy wooden packing
Name : Distribution Transformer
Cooling : AN or ANAF
Capacity : 100 kVA or Customized
Rated H. V. : 11 kV or Customized
Type : Dry Type
Impedance : 4% or Customized
Contact Now

Three Phases Dry Type cast resin Transformer with ANAF cooling way


Dry Type Transformer Structure:

1. Iron core:
Made of high-quality grain orientation cold rolled silicon steel sheet, it adopts 45° full-inclined joint structure and five-grade stepping.
2. Pouring coil:
It adopts F grade insulated copper conductor as the conductor, with glass fiber and epoxy resining composite material for insulation.
3. Foil type coil:
It is automatically winded by foil type coil winding machine and adopts argon shield technology to perform internal welding.
4. Cast-foil Coil:
Adopting the entire section of copper foil, with the F-class turn insulation, low voltage winding is wound by the special low-voltage foil winding machine. The foil coil resolves such understanding problems as large short-circuit stress, uneven ampere turn, poor heat dissipation, existing the winding spiral angle as well as unsteady manual welding quality due to low voltage and large current coil winding products. At the same time, the winding end in our company is treated with resin potting, solidification to make shape, moisture-proof and anti-fouling. The lead copper platoon is automatically welded by argon arc welding.

Dry Type Transformer Parameters


No.ItemsUnit
I Basic Information     
1Rated Voltage ratiokV20kV / 0.433 kV
1.01Rated CapacitykVA100
1.02Applicable Standards IEC 60076
1.03Manufacturer Pearl Electric
1.04Country of Origin China
II Electric Performance     
2.06Insullation Class Class H
2.07Temperature Rise (@40℃ ambient temperature)K125K
2.08Cooling Method AN
2.09Tapping Ranging ±2*2.5%
2.1Vector Group Dyn11
2.11Noise leveldB48
2.12Impedance%4
2.13No-load lossW450
2.14Load Loss (@120℃)W1670
2.15Local Partial dischargepC<10PC
2.16Impulse Withstand Voltage (HV/LV)kV75/0
2.17Power Frequency Withstand Voltage
(HV/LV)
kV28/3
2.18Rated Duration of Short Circuits2
III Materials & Accessories     
3.01Core Materials Silicon Steel Sheet
3.02Winding Materials Copper conductor/foil
3.03Insulation methods HV vacuum cast / LV impregnant
3.04Main Insulation Materials Epoxy Resin
3.05Tap-changerpcsOff-load tap-changer
3.06Sensor for Temperature Alarm and TrippcsYes, contact provided
3.07Protective EnclosurepcsIP00


Ageing and transformer insulation lifetime
Experience indicates that the normal lifetime of a transformer is some tens of years. It cannot
be stated more precisely, because it may vary even between identical units, owing in
particular to operating factors, which may differ from one transformer to another. With few
exceptions a transformer rarely operates at 100 % of rated current throughout its lifetime.
Other heating factors such as insufficient cooling, harmonics, over fluxing and/or unusual
conditions as described in 60076-11 could also affect the life of the transformer.
When heat, which is mainly due to the transformer losses, is transferred to the insulation
system, a chemical process begins. This process changes the molecular structure of the
materials which form the insulation system. The ageing rate increases with the amount of heat
transferred to the system. This process is cumulative and irreversible, which means that the
materials do not regain their original molecular structure when the heat supply stops and the
temperature decreases. The thermal index of the insulation system is stated in the manufacturer’s documentation and is also written on the rating plate. It is assumed that failing insulation due to ageing is one of the causes of end of lifetime of the transformer.

Further it is assumed that the ageing rate varies with temperature according to the Arrhenius’
equation. See Annex A for additional background information. The two constants in Arrhenius’
equation should ideally be determined by means of thermal endurance testing. In cases where
data from such testing is missing, this guide provides estimated constants, which are
calculated on the basis of the following assumptions:
– a temperature increase of 6 K doubles the ageing rate. 6 K is an estimated value for the
whole winding linked with the value of specific materials used in the winding;
– another value for this doubling rate should be used when supported by thermal endurance
tests on the complete electrical insulation system (EIS), according to IEC 60216-1;
– insulation failures are the cause of end of life of the transformer.
Applied Standard
GB/T10228 , GB1094.11 , IEC60076-11 , DIN42523



If you need price and technical sheet about cast resin dry type transformer, please feel free to contact us by below contact way:


Miss Sandy | Oversea Dept.

Pearl Electric Co., Ltd.

Add: No. 118 Donghuan Road, Donghuan Street, Panyu Distric, Guangzhou City, Guangdong Province, China. ZIP: 511400

Tel:(8620)29026603

Whatsapp:8618826241798

LineID: 008618826241798

Email: zhoux@pearlelectric.com

Skype:zhoux@pearlelectric.com

Web:pearl-electric.en.made-in-china.com

Web:oil-immersedtransformer.com



Product Tags:

air cooled transformer dry type

      

dry type power transformer

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Three Phases Dry Type cast resin Transformer with ANAF cooling way Images

Inquiry Cart 0
Send your message to this supplier
 
From:
To: Pearl Electric Co.,Ltd.
Subject:
Message:
Characters Remaining: (0/3000)